Points
to note
A Where two or more cracks
are close together these may be stitched using one continuous
length of HeliBar which must be long enough to extend 500mm beyond
the outer cracks. e.g. if there are three cracks, each 250mm apart,
then the overall length of HeliBar required would be 1.5m.
B The horizontal slot,
normally the mortar bed, can be cut using a twin diamond blade
chaser with vacuum attachment, an angle grinder or a mortar chisel.
C All mortar must be removed,
together with any loose debris, to ensure a sound bond.
D Prepare the slot with
HeliBond Primer or thoroughly wet the slot with clean water.
E As standard, slots should
be 10mm wide to accommodate the 6mm diameter HeliBar. For thin
joints use 4.5mm HeliBar
F HeliBond grout
is the recommended bonding agent. PolyPlus resin is used for smaller
jobs and where loads are to be rapidly applied.
|